Màng RO áp suất cực thấp XLP-8040
USAGE
It is applicable to the desalination of municipal water, groundwater with salt concentration less than 1000ppm. It can be widely used in pure water preparation and related industries.
SPECIFICATIONS & PARAMETERS
Model | Active Membrane Area ft2(m2) |
Concentrate Channel Spacer (mil) |
Permeate Flow GPD(m3/d) |
Stable Rejection Rate (%) |
Minimum Rejection Rate (%) |
XLP-8040 | 440(40.9) | 28 | 11000(41.6) | 99.20 | 99.00 |
STANDARD TEST CONDITION
Concentration of Solution (NaCl) | Temperature(℃) | pH Value | Operating Pressure psi(MPa) | Recovery Rate(%) |
500mg/L | 25 | 7.5-8 | 100(0.69) | 15 |
Notes: The permeate flow of single membrane element may vary with in ±15%.
Operating Limits and Conditions of Membrane Element:
Max.Working Pressure | 600 psi(4.14MPa) |
Max. FeedWater Temperature | 45 ℃ |
Max. FeedWaterSDI15 | 5.0 |
Max. Feed Water Flow | 17m3/h |
Free Chlorine Concentration of FeedWater | 0.1mg/L |
pH Range of FeedWaterDuring Continuous Operation | 3-10 |
pH Range of FeedWaterDuring Chemical Cleaning | 1-13 |
Max. Pressure Drop of Single Membrane Element | 15psi(0.1Mpa) |
Copyright © 2022 by VIETCHEM. All rights reserved