USAGE

It is applicable to the desalination of raw water with salt concentration less than 500ppm. It can be widely applied to various small size household water purification, mineral water machine and energy machine etc..

SPECIFICATIONS & PARAMETERS
Model Active Membrane
Area ft2(m2)
Permeate Flow
GPD(m3/d)
Stable Rejection
Rate (%)
Solution Type
NF-2012 6.3(0.59) 150(0.57) 30-50 NaCl
>96 MgSO4
STANDARD TEST CONDITION
Concentration of Solution Temperature(℃) pH Value Operating Pressure psi(MPa) Recovery Rate(%)
500mg/L NaCl 25 7.5-8 70(0.48) 15
2000mg/L MgSO4 25 7.5-8 70(0.48) 15

Notes: The permeate flow of single membrane element may vary with in ±15%.

Operating Limits and Conditions of Membrane Element:

Max.Working Pressure 300 psi(2.07MPa)
Max. FeedWater Temperature 45 ℃
Max. FeedWaterSDI15 5.0
Free Chlorine Concentration of FeedWater 0.1mg/L
pH Range of FeedWaterDuring Continuous Operation 3-10
pH Range of FeedWaterDuring Chemical Cleaning 2-12